Showing all 8 results

Show sidebar
Part #: ME590015P

Connects Draeger Medical monitor output to GE Healthcare monitor or ultrasound input (specific models).

i cable ECG. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta and M540 monitor (not including Axiom Sensis ) to all GE monitors and select ultrasound models: Vivid 5, 7, E9, E95, 11 pin patient ECG input. NOTE: connection from M540 monitor requires adapter #MS20662 available from Draeger.

Part #: ME590015J

Connects Draeger-Siemens monitor output to Zoll Medical defibrillator input.

i cable ECG. 14 pin MDR  output of the Draeger -Siemens SC7000, SC8000, SC9000, Infinity Delta Series and M540 monitors (not including Axiom Sensis ) to Zoll R, X or M Series defibrillator, AAMI 6 pin ECG input. NOTE: connection from M540 monitor requires adapter #MS20662 available from Draeger.

Part #: ME590257H

Adapts Draeger Siemens monitor single output to be multiple phone jack outputs.

i cable ECG & IBP Multiplier.  14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series and M540 Monitors (not including Axiom Sensis) adapted to be 1/4″ two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP signal to desirable peripheral monitors. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

 

Part #: ME590092

Connects Draeger Siemens monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series Monitors (not including Axiom Sensis) 14 pin MDR output to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.  NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger.

Part #: ME590134F

Connects Spacelabs monitor alarm output to the nurse call headwall jack.

i cable Nurse Call. 14 pin MDR normally open alarm output of Spacelabs 91369, 91370, 90387, Qube and Xpreazzon monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590015L

Connects Draeger Siemens monitor to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series Monitors (not including Axiom Sensis) to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger.

Part #: ME550MDR

Adapts Draeger Medical monitor output to Cardiac Rhythm Management Pacer Programmer cables.

i cable ECG Adapter. 14 pin MDR output of Draeger Delta or Delta XL monitor (not including the AXIOM SENSIS) adapted to mate with CRM pacemaker programmer cable via the 1/4″ two circuit phone jack. Use in tandem with 1/4″ phone plug pacer programmer cables. This adapter also enables connection to other physiologic monitors via 1/4″ phone plug accessory cables.

Part #: ME590248G

Adapts Draeger Medical monitor single output to be three outputs.

i cable ECG & IBP Multiplier. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series, Axiom Sensis, and M540 monitors adapted to be three parallel ECG and IBP outputs.  Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitors via 14 pin MDR interconnect cables.