Same Day Shipping
On many popular products
Our monitor slave cables and adapters are used for transferring ECG and/or IBP signal from a host physiologic monitor to a secondary, slaved monitor. Commonly connected devices can include an anesthesia or bedside monitor, defibrillator, ultrasound, balloon pump, cardiac output monitor, and pacer programmer.
Showing 1–30 of 51 results
i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to the LifePak defibrillator LP12, LP15, LP20, LP20e with code management module, 12 pin ECG input. This cable is also compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 1/4″ phone plug output from the Philips monitor or Maquet-Datascope balloon pump to the Zoll R, X and M series defibrillator ECG input. Also from the Philips monitor to the balloon pump input or ultrasound, AAMI 6 pin ECG input. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized analog audio waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG or IBP. 1/4″ phone plug output of the Philips monitor or balloon pump to Philips/Siemens ultrasound or Edwards LifeSciences Vigilance II , HemoSphere monitor, 1/4″ AUX ECG input. Also connects the 1/4″ IBP output jack of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the balloon pump, continuous cardiac output monitor or ultrasound, AUX ECG input. Maguire 257 and 414 Series Interconnect systems are designed to deliver synchronized waveforms and simultaneous audio signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable IBP. 9 pin Hypertronics Low-Level BP output of the Getinge Datascope CS300, Maquet CardioSave balloon pump to the Philips monitor, 12 pin input. Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.
i cable ECG. 9 pin ‘Defib/Sync’ output of the GE Carescape One monitor or PDM module to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.
i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to specific GE device inputs, all monitors and ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin ECG input. Refer to part# ME590184F for connection to other GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 5 pin output from the Nihon Kohden monitor to the Maquet-Datascope balloon pump, 1/4 AUX ECG input.
i cable ECG. 7 pin ‘Sync In/Marker Out’ of Zoll R Series Defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) to the Philips monitor or ultrasound, 12 pin ECG input.
i cable ECG & IBP. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ 2 circuit phone plug AUX ECG & IBP inputs.
i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to all GE monitors and specific ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin patient ECG input.
i cable ECG or IBP. TT253 ‘HLo’ output of the Spacelabs monitor module to balloon pump, AUX ECG or IBP. Also connects to Vigilance II, Hemosphere continuous cardiac output monitor or Philips Healthcare, Siemens ultrasound AUX ECG input, 1/4″ two circuit phone plug input.
i cable ECG. 9 pin ‘Defib/Sync’ output of the GE Carescape One monitor or PDM module to the LifePak defibrillator LP12, LP15, LP20, LP20e with code Management module, 12 pin ECG input.
i cable ECG & IBP. 1/4″ (6.35mm) phone plug (green) and 1/8″ (3.5mm) phone plug (red) output of the Philips monitor with blood pressure module to the CardioSave, CS100, CS300, or Arrow balloon pump or to the Volcano S5 IVUS Imaging System, 1/4″ (6.35mm) phone plug AUX ECG & IBP inputs.
i cable IBP. 9 pin Hypertronics low level blood pressure output of Datascope CS300 or Maquet Cardiosave balloon pump to the GE Healthcare monitor input. Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.
i cable ECG and IBP. 9 pin ‘Defib/Sync’ output of the GE Healthcare Monitor Carescape One and PDM module to Edwards Hemosphere or Vigilance II monitor as a 1/4″ (6.35mm) green phone plug AUX ECG and 1/8″ (3.5mm) red phone plug IBP inputs.
i cable ECG. 7 pin mini DIN ‘Defib Sync’ output of the GE monitor to Zoll X, R or M Series defibrillator, AAMI 6 pin ECG input.
i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to Zoll X, R or M Series, AAMI 6 pin patient ECG input.
i cable ECG & IBP. 7 pin mini DIN “Defib Sync” output of the GE monitor to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ phone plug AUX ECG & IBP inputs.
i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the Edwards Vigilance II or Hemosphere, 1/4″ two circuit red phone plug AUX ECG input and 1/8″ (3.5mm) green two circuit phone plug IBP input. Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. TT253 ‘HLo’ output of Spacelabs Healthcare monitor to Zoll Medical defibrillator or Maquet-Datascope balloon pump, 6 pin AAMI patient ECG input.
i cable ECG Adapter. Allows the use of a Philips Healthcare 5 wire, 12 pin ECG patient cable with GE Healthcare monitor as 11 pin patient ECG input. Not compatible with the 3 wire patient cable.
i cable ECG. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta and M540 monitor (not including Axiom Sensis ) to all GE monitors and select ultrasound models: Vivid 5, 7, E9, E95, 11 pin patient ECG input. NOTE: connection from M540 monitor requires adapter #MS20662 available from Draeger.
i cable IBP. Output of Abbott / Hospira, Medex, ICU Medical Transpac 4 transducer cable to Draeger Infinity Series monitor, IBP input. Requires the use of Draeger #5731281E530U IBP Y cable.
i cable ECG. Witt Series IV monitors with digital front end, BNC output to Zoll M, R, or X Series defibrillator, AAMI 6 pin ECG input.
i cable ECG. 6 pin LEMO output of the GE monitor to Zoll X, R or M Series, AAMI 6 pin ECG input.
i cable ECG. 14 pin MDR output of the Draeger -Siemens SC7000, SC8000, SC9000, Infinity Delta Series and M540 monitors (not including Axiom Sensis ) to Zoll R, X or M Series defibrillator, AAMI 6 pin ECG input. NOTE: connection from M540 monitor requires adapter #MS20662 available from Draeger.
i cable ECG. 7 pin mini DIN “Defib Sync” output of the GE monitor to LifePak defibrillator LP12, LP15, LP20, LP20e with Code Management Module, 12 pin patient ECG input.
i cable ECG. 7 pin output of the LifePak LP12 and LP15 defibrillator to Philips Healthcare monitor and ultrasound, 12 pin patient ECG input.
i cable ECG. 1/8″ (3.5mm) two circuit output of the Zoll PD and M defibrillator to the Philips monitor or ultrasound, 12 pin ECG input.
i cable ECG. TT253 ‘HLo’ output of Spacelabs modules to all GE monitors and select ultrasound models Vivid 5, 7, E9, E95, 11 pin patient ECG input.