Part #: ME590142R

Connects Respironics V60, V200, V1000, or Esprit series alarm output to the nurse call headwall jack.

i cable Nurse Call. 1/4″ phone plug three circuit alarm output of a Respironics V-60, V-200, V-1000 or Esprit series ventilator to the central station alarm monitoring system input, 1/4″ two circuit phone plug. An integrated switch allows a selection between ‘normally open or ‘ normally closed‘ system protocols. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590238E

Connects Puritan-Bennett ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. 4 pin Hirose normally open alarm output of  the Puritan Bennett 700, 740, 760, 840 or 980 series ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590143NO

Expands the number of inputs at the headwall for connection to the nurse call system.

i cable Nurse Call Multiplier. Normally open alarm input at headwall jack (1/4″ phone plug ) expanded to be three parallel 1/4″ phone jacks.  Use to increase the number of connected devices at the headwall, turning the average room into a more intensive care unit! This product is compatible with normally open device alarm cables.

Part #: ME590138-1

Connects Maquet ventilator alarm output to the nurse call headwall jack. (Copy)

i cable Nurse Call.  616 jack normally open alarm output of Maquet Servo-i, Servo-n, Servo-s and Servo-U ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590138

Connects Maquet ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call.  616 jack normally open alarm output of Maquet Servo-i, Servo-n, Servo-s and Servo-U ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590120

Connects Viasys, Pulmonetis, Carefusion ventilators alarm outputs to the nurse call headwall jack.

i cable Nurse Call. RJ11 normally open alarm output of Viasys/Pulmonetics LTV Series and Carefusion Enve ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590131

Connects Hamilton G5 ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of Hamilton G5 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590147

Connects GE Healthcare Engstrom Carestation, Carescape R860 ventilators alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of GE Healthcare Engstrom, Carestation and Carescape R860 ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590220

Connects Hamilton ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of Hamilton Galileo, Raphael and G5 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590142H

Connects Respironics Trilogy EVO, 100, BiPAP V30 ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ9 normally closed alarm output of Respironics Trilogy EVO, 100, EV300 or BiPAP V30 ventilator to 1/4″ 2 circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590145F

Connects Viasys, Respironics, Cardinal Health, Carefusion VELA or AVEA ventilators alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ12 normally open alarm output of Viasys, Cardinal Health, Carefusion Vela or Avea Series ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590142K

Connects Respironics Trilogy EVO, 100, BiPAP V30 ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ9 normally open alarm output of Respironics Trilogy EVO, 100, or BiPAP V30 ventilator output to 1/4″ 2 circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590258N

Connects Respironics BiPAP Vision ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. BNC alarm output of Philips Respironics BiPAP Vision (not ESPRIT) ventilator alarm output to a 1/4″ two circuit right angle phone plug. Device settings will determine open/closed status. Click to view related info regarding equipment normally open/closed protocol.

When used as normally open, this device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590153E

Connects ResMed ventilator alarm output to the nurse call headwall jack. Two pieces for improved ruggedness.

i cable Nurse Call. Normally open alarm output of ResMed Astral 150 ventilator. Includes 2 pieces uniquely engineered to improve the ruggedness of the vent alarm output.  1) Adapter ME550ASTRAL: 5 pin to 1/8″  phone jack and 2) Alarm cable ME590333N: 1/8″ two circuit phone plug to  1/4″  two circuit right angle phone plug input to headwall jack. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590142E

Connects Hospira/Abbott infusion pump or Masimo monitor, pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call.  1/4″ two circuit phone plug alarm output of Hospira/Abbott Plum A infusion pump or Masimo ROOT monitor, Rad 8, Rad 87 and Rad 97 pulse oximeter to a 1/4″ two circuit right angle phone plug. Some device settings will determine open/closed status. When used with a normally open system protocol this device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590200K

Connects Cardinal Health “Inspiration” ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ11 normally open alarm output of Cardinal Health “Inspiration” ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590220K

Connects Hamilton ODU ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. 6 pin ODU normally open alarm output of Hamilton C1, C2, C3, C6 & T1 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590148

Connects Masimo Radical 7 pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15HD normally open alarm output of Masimo Radical 7 SpO2 Pulse Oximeter to 1/4″ 2 ckt right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590135

Connects Covidien Nellcor pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of Covidien Nellcor N-395, N-560, N-595, N-600 and PM1000N pulse oximeter to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590153

Connects ResMed ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call.  Normally closed alarm output of ResMed Astral 150 ventilator. Includes 2 pieces uniquely engineered to improve the ruggedness of the vent alarm output.  1) Adapter ME550ASTRALC: 5 pin to 1/8″  phone jack and 2) Alarm cable ME590333N: 1/8″  two circuit phone plug to  1/4″  two circuit right angle phone plug.

Part #: ME590138G

Connects Ventec Life Systems VOCSN ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ9 4P4C normally open alarm output of Ventec Life Systems VOCSN ventilator to the central station monitoring system, 1/4″ two circuit right angle phone plug input. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590139

Connects Draeger Evita, Savina ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. 6 pin DIN normally open alarm output of Draeger Evita 2, 4, & XL or Savina ventilator to a 1/4″ two circuit right angle phone plug. Not for use with Infinity Series. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590147J

Connects GE Healthcare Engstrom Carestation, Carescape R860 output to the nurse call headwall jack.

i cable Nurse Call. Normally open alarm output of GE Healthcare Carestation or Carescape R860 ventilator to the input at the headwall jack which transmits device alarms to the central nurses station. Set includes 2 pieces: 1) DB15 to 1/4″ 2 circuit right angle phone plug. 10 ft length. 2) Required GE isolation cable #2070436-001. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590145J

Connects Nellcor Covidien pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ12 normally open alarm output of Nellcor PM100N SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590145G

Connects Philips Healthcare Intellivue MX750 and MX800 monitor output to the nurse call headwall jack.

i cable Nurse Call normally open output of Philips Intellivue MX750 and MX 800 monitor RJ12 to 1/4″ 2 ckt right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow up to three device connections.

Part #: ME562N

Connects the GE Healthcare R860 ventilator output to the nurse call headwall jack. and Cerner EMR system.

i cable Nurse Call – Data. GE Healthcare R860 Ventilator DB15 to Nurse Call and EMR system inputs.

Part #: ME590152F

Connects Puritan-Bennett Covidien ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. 8 pin Hirose normally open alarm output of Puritan Bennett Covidien 540 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590147G

Connects Datex-Ohmeda ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. 6 pin mini DIN normally open alarm output of Datex-Ohmeda TruSat ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590135G

Connects Dixtal Novametrix pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. DB25 normally open alarm output of Dixtal Novametrix SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug.This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590145K

Connects Covidien Nellcor pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ12 normally closed output of Covidien Nellcor PM100N SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug.