Showing 1–12 of 30 results

Show sidebar
Part #: ME590238E

Connects Puritan-Bennett ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. 4 pin Hirose normally open alarm output of  the Puritan Bennett 700, 740, 760, 840 or 980 series ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590138

Connects Maquet ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call.  616 jack normally open alarm output of Maquet Servo-i, Servo-n, Servo-s and Servo-U ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590142R

Connects Respironics V60, V200, V1000, or Esprit series alarm output to the nurse call headwall jack.

i cable Nurse Call. 1/4″ phone plug three circuit alarm output of a Respironics V-60, V-200, V-1000 or Esprit series ventilator to the central station alarm monitoring system input, 1/4″ two circuit phone plug. An integrated switch allows a selection between ‘normally open or ‘ normally closed‘ system protocols. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590120

Connects Viasys, Pulmonetis, Carefusion ventilators alarm outputs to the nurse call headwall jack.

i cable Nurse Call. RJ11 normally open alarm output of Viasys/Pulmonetics LTV Series and Carefusion Enve ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590131

Connects Hamilton G5 ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of Hamilton G5 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590147

Connects GE Healthcare Engstrom Carestation, Carescape R860 ventilators alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of GE Healthcare Carestation and Carescape R860 ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590220

Connects Hamilton ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of Hamilton Galileo and Raphael ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590258N

Connects Respironics BiPAP Vision ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. BNC alarm output of Philips Respironics BiPAP Vision (not ESPRIT) ventilator alarm output to a 1/4″ two circuit right angle phone plug. Device settings will determine open/closed status. Click to view related info regarding equipment normally open/closed protocol.

When used as normally open, this device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590153E

Connects ResMed ventilator alarm output to the nurse call headwall jack. Two pieces for improved ruggedness.

i cable Nurse Call. Normally open alarm output of ResMed Astral 150 ventilator. Includes 2 pieces uniquely engineered to improve the ruggedness of the vent alarm output.  1) Adapter ME550ASTRAL: 5 pin to 1/8″  phone jack and 2) Alarm cable ME590333N: 1/8″ two circuit phone plug to  1/4″  two circuit right angle phone plug input to headwall jack. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590142E

Connects Hospira/Abbott infusion pump or Masimo monitor, pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call.  1/4″ two circuit phone plug alarm output of Hospira/Abbott Plum A infusion pump or Masimo ROOT monitor, Rad 8, Rad 87 pulse oximeter to a 1/4″ two circuit right angle phone plug. Some device settings will determine open/closed status. When used with a normally open system protocol this device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590200K

Connects Cardinal Health ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ11 normally open alarm output of Cardinal Health “Inspiration” ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590220K

Connects Hamilton ODU ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. 6 pin ODU normally open alarm output of Hamilton C1, C2, C3 & T1 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.