ECG Interconnect Cables enable you to transfer ECG signal from the output of one physiologic monitor to the input of another. The use of interconnect cables helps create an integrated system and eliminates the need for redundant sets of patient cables and electrodes.

Showing 1–30 of 44 results

Show sidebar
Part #: ME590006K

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump to Physio Control LifePak defibrillator input.

i cable ECG. 1/4″ phone plug output of the Philips monitor or  balloon pump to the LifePak defibrillator LP12, LP15, LP20, LP20e with code management module, 12 pin ECG input. This cable is also compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590335

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to Zoll Medical defibrillator input or ultrasound input.

i cable ECG. 1/4″ phone plug output from the Philips monitor or Maquet-Datascope balloon pump to the Zoll R, X and M series defibrillator ECG input. Also from the Philips monitor to the balloon pump input or ultrasound, AAMI 6 pin ECG input. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized analog audio waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590338J

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG or IBP. 1/4″ phone plug output of the Philips monitor or balloon pump to Philips/Siemens ultrasound or Edwards LifeSciences Vigilance II , HemoSphere monitor, 1/4″ AUX ECG input.  Also connects the 1/4″ IBP output jack of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the balloon pump, continuous cardiac output monitor or ultrasound, AUX ECG input. Maguire 257 and 414 Series Interconnect systems are designed to deliver synchronized waveforms and simultaneous audio signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590185M

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG. 9 pin ‘Defib/Sync’ output of the GE Carescape One monitor or PDM module to balloon pump, Vigilance II,  Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.

Part #: ME590132

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump to GE Healthcare monitor or ultrasound input (specific models).

i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to specific GE device inputs, all monitors and ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin ECG input. Refer to part# ME590184F for connection to other GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590336

Connects Nihon Kohden output to Maquet-Datascope balloon pump input.

i cable ECG. 5 pin output from the Nihon Kohden monitor to the Maquet-Datascope balloon pump, 1/4 AUX ECG input.

Part #: ME590009XRN

Connects Zoll R Series defibrillator output to Philips Healthcare monitor, ultrasound input.

i cable ECG.  7 pin ‘Sync In/Marker Out’ of Zoll R Series Defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) to the  Philips monitor or ultrasound, 12 pin ECG input.

Part #: ME590264

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG.  7 pin mini DIN “Defib Sync” output of GE monitor to balloon pump, Vigilance II,  Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.

Part #: ME590185Q

Connects GE Healthcare monitor output to GE Healthcare monitor or ultrasound input (specific models).

i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to all GE monitors and specific ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin patient ECG input.

Part #: ME590027

Connects Spacelabs monitor output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG or IBP. TT253 ‘HLo’ output of the Spacelabs monitor module to balloon pump, AUX ECG or IBP. Also connects to Vigilance II, Hemosphere continuous cardiac output monitor or Philips Healthcare, Siemens ultrasound AUX ECG input,  1/4″ two circuit phone plug input.

Part #: ME590185K

Connects GE Healthcare monitor output to Physio-Control LifePak defibrillator input.

i cable ECG. 9 pin ‘Defib/Sync’ output of the GE Carescape One monitor or PDM module to the LifePak defibrillator LP12, LP15, LP20, LP20e with code Management module, 12 pin ECG input.

Part #: ME579P

Extends the Philips Healthcare 3, 5, or 10 wire patient cable.

i cable Extension. 12 pin Philips patient cable extended for 3 wire, 5 wire or 10 wire ECG patient cables. 6 foot length.

Part #: ME590260

Connects GE Healthcare monitor output to Zoll Medical defibrillator input.

i cable ECG. 7 pin mini DIN ‘Defib Sync’ output of the GE monitor to Zoll X, R or M Series defibrillator, AAMI 6 pin ECG input.

Part #: ME590185

Connects GE Healthcare monitor output to Zoll Medical defibrillator input.

i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to Zoll X, R or M Series, AAMI 6 pin patient ECG input.

Part #: ME590202F

Extends the 1/4″ phone plug cable connection.

i cable Extension. 1/4″ two circuit phone plug adapted to 1/4″ two circuit phone jack. For use with AUX ECG or IBP inputs. 6 foot length.

Part #: ME590359

Connects Spacelabs Healthcare monitor output to the Zoll defibrillator input or balloon pump input.

i cable ECG. TT253 ‘HLo’ output of Spacelabs Healthcare monitor to Zoll Medical defibrillator or Maquet-Datascope balloon pump, 6 pin AAMI patient ECG input.

Part #: ME590015P

Connects Draeger Medical monitor output to GE Healthcare monitor or ultrasound input (specific models).

i cable ECG. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta and M540 monitor (not including Axiom Sensis ) to all GE monitors and select ultrasound models: Vivid 5, 7, E9, E95, 11 pin patient ECG input. NOTE: connection from M540 monitor requires adapter #MS20662 available from Draeger.

Part #: ME579G

Extends the GE Healthcare 3, 5, or 10 wire patient cable.

i cable ECG Extension. 11 pin GE patient cable extended for 3 wire, 5 wire or 10 wire ECG cables. 6 foot length.

Part #: ME579

Extends the 6 pin AAMI patient cable.

i cable ECG Extension. 6 pin AAMI patient cable extended for ECG patient cables. 6 foot length.

Part #: ME590258

Connects Witt Series monitor output to Zoll Medical defibrillator input.

i cable ECG. Witt Series IV monitors with digital front end, BNC output to Zoll M, R, or X Series defibrillator, AAMI 6 pin ECG input.

Part #: ME590032
Part #: ME590015J

Connects Draeger-Siemens monitor output to Zoll Medical defibrillator input.

i cable ECG. 14 pin MDR  output of the Draeger -Siemens SC7000, SC8000, SC9000, Infinity Delta Series and M540 monitors (not including Axiom Sensis ) to Zoll R, X or M Series defibrillator, AAMI 6 pin ECG input. NOTE: connection from M540 monitor requires adapter #MS20662 available from Draeger.

Part #: ME590301

Connects Zoll Medical M Series defibrillator output to Maquet-Datascope balloon pump input.

i cable ECG. 1/8″ two circuit phone plug output of the Zoll Medical PD and M Series, CCT or Welch Allyn defibrillators to the Getinge-Maquet-Datascope balloon pump or ultrasound, AAMI 6 pin ECG input.

Part #: ME590185F

Connects GE Healthcare monitor output to GE ultrasound input (specific models)

i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to Vivid i or Vivid Q ultrasound, 7 pin Redel AUX ECG input.

Part #: ME590261

Connects GE Healthcare monitor output to Physio Control LifePak defibrillator input.

i cable ECG. 7 pin mini DIN “Defib Sync” output  of the GE monitor to LifePak defibrillator LP12, LP15, LP20, LP20e with Code Management Module, 12 pin patient ECG input.

Part #: ME590036K

Connects Spacelabs module output to Physio Control LifePak defibrillator input.

i cable ECG.  TT253 ‘HLo’ output of the Spacelabs module to LifePak defibrillator LP12, LP15, LP20, LP20e with Code Management Module, 12 pin patient ECG input.

Part #: ME590008BX

Connects Physio-Control LifePak LP12, LP15 defibrillator output to Philips Healthcare monitor, ultrasound input.

i cable ECG.  7 pin output of the LifePak LP12 and LP15 defibrillator to Philips Healthcare monitor and ultrasound, 12 pin patient ECG input.

Part #: ME590009X

Connects Zoll M Series defibrillator output to Philips Healthcare monitor, ultrasound input.

i cable ECG. 1/8″ (3.5mm) two circuit output of the Zoll PD and M defibrillator to the Philips monitor or ultrasound, 12 pin ECG input.

Part #: ME590359G

Connects Spacelabs Healthcare monitor output to GE Healthcare monitors or specific model ultrasound input.

i cable ECG.  TT253 ‘HLo’ output of Spacelabs modules to all GE monitors and select ultrasound models Vivid 5, 7, E9, E95, 11 pin patient ECG input.

Part #: ME590132J

Connects Physio-Control LifePak LP12 and LP15 output to GE Healthcare monitors and specific ultrasound inputs.

i cable ECG. 9 pin Hypertronics output of Physio Control Defibrillator LP12 and LP15 to all GE monitors and select ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin patient ECG input.