Same Day Shipping
On many popular products
Showing 1–30 of 126 results
i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to the LifePak defibrillator LP12, LP15, LP20, LP20e with code management module, 12 pin ECG input. This cable is also compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 1/4″ phone plug output from the Philips monitor or Maquet-Datascope balloon pump to the Zoll R, X and M series defibrillator ECG input. Also from the Philips monitor to the balloon pump input or ultrasound, AAMI 6 pin ECG input. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized analog audio waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable IBP. Output of the Edwards TruWave disposable transducer cable to the LifePak LP12, LP15 or Zoll X, M Series defibrillator, MS 6 pin IBP input.
i cable Nurse Call. 1/4″ phone plug three circuit alarm output of a Respironics V-60, V-200, V-1000 or Esprit series ventilator to the central station alarm monitoring system input, 1/4″ two circuit phone plug. An integrated switch allows a selection between ‘normally open or ‘ normally closed‘ system protocols. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. 4 pin Hirose normally open alarm output of the Puritan Bennett 700, 740, 760, 840 or 980 series ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call Multiplier. Normally open alarm input at headwall jack (1/4″ phone plug ) expanded to be three parallel 1/4″ phone jacks. Use to increase the number of connected devices at the headwall, turning the average room into a more intensive care unit! This product is compatible with normally open device alarm cables.
i cable ECG or IBP. 1/4″ phone plug output of the Philips monitor or balloon pump to Philips/Siemens ultrasound or Edwards LifeSciences Vigilance II , HemoSphere monitor, 1/4″ AUX ECG input. Also connects the 1/4″ IBP output jack of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the balloon pump, continuous cardiac output monitor or ultrasound, AUX ECG input. Maguire 257 and 414 Series Interconnect systems are designed to deliver synchronized waveforms and simultaneous audio signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable Nurse Call. 616 jack normally open alarm output of Maquet Servo-i, Servo-n, Servo-s and Servo-U ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. 616 jack normally open alarm output of Maquet Servo-i, Servo-n, Servo-s and Servo-U ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. RJ11 normally open alarm output of Viasys/Pulmonetics LTV Series and Carefusion Enve ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. DB15 normally open alarm output of Hamilton G5 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. DB15 normally open alarm output of GE Healthcare Engstrom, Carestation and Carescape R860 ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable IBP. 9 pin Hypertronics Low-Level BP output of the Getinge Datascope CS300, Maquet CardioSave balloon pump to the Philips monitor, 12 pin input. Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.
i cable Nurse Call. DB15 normally open alarm output of Hamilton Galileo, Raphael and G5 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. RJ9 normally closed alarm output of Respironics Trilogy EVO, 100, EV300 or BiPAP V30 ventilator to 1/4″ 2 circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
Never lose or misplace vital cables again. Protect your assets by securing the interconnect cable to its related equipment. Having medical cables and equipment tethered ensures your readiness to connect every time! This 16-piece kit allows you to safe guard FOUR essential cables and includes cable leashes with adhesive tab ends, set screws, hex wrenches and alcohol swabs. *Interconnect adapters shown in image sold separately.
i cable ECG & IBP Multiplier. Mindray N1 Monitors output adapted to be 1/4″ two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP analog audio signal to desirable peripheral monitors. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG & IBP Multiplier. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module adapted to be 1/4″ two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP signal to desirable peripheral monitors. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 9 pin ‘Defib/Sync’ output of the GE Carescape One monitor or PDM module to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.
i cable ECG or IBP Multiplier. 1/4″ three circuit ECG output of the Philips monitor, Maquet-Datacope balloon pump or other 1/4″ output to be three parallel phone jacks. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. This multiplier not only expands the device’s single analog output, it can also expand the output of a MAGUIRE 257 Series multiplier or 414 Series Boom Cabling System. Use this product in combination with MAGUIRE multiplier cables to deliver ECG or IBP signal to desirable peripheral monitors. (excluding the bifurcated dual signal cable). Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG & IBP Multiplier. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series, Axiom Sensis, and M540 monitors adapted to be three parallel ECG and IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitors via 14 pin MDR interconnect cables.
i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to specific GE device inputs, all monitors and ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin ECG input. Refer to part# ME590184F for connection to other GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 5 pin output from the Nihon Kohden monitor to the Maquet-Datascope balloon pump, 1/4 AUX ECG input.
i cable ECG. 7 pin ‘Sync In/Marker Out’ of Zoll R Series Defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) to the Philips monitor or ultrasound, 12 pin ECG input.
i cable ECG Adapter. 7 pin ‘Sync In/Marker Out‘ of Zoll R Series defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) adapted to mate with CRM pacemaker programmer cables via the 1/4″ two circuit phone jack. See also our multi-defibrillator adapter, part# ME550DFB3.
i cable ECG & IBP. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ 2 circuit phone plug AUX ECG & IBP inputs.
Connects the Physio-Control and Zoll Medical defibrillator outputs to CRM Pacer Programmer cables.
i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multipliers or MAGUIRE 414 Series Boom Cabling System to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs. Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 7 pin mini DIN “Defib Sync” output of GE monitor to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.
i cable Nurse Call. RJ12 normally open alarm output of Viasys, Cardinal Health, Carefusion Vela or Avea Series ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.