Part #: ME590006K

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump to Physio Control LifePak defibrillator input.

i cable ECG. 1/4″ phone plug output of the Philips monitor or  balloon pump to the LifePak defibrillator LP12, LP15, LP20, LP20e with code management module, 12 pin ECG input. This cable is also compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590335

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to Zoll Medical defibrillator input or ultrasound input.

i cable ECG. 1/4″ phone plug output from the Philips monitor or Maquet-Datascope balloon pump to the Zoll R, X and M series defibrillator ECG input. Also from the Philips monitor to the balloon pump input or ultrasound, AAMI 6 pin ECG input. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized analog audio waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME584F

Connects Edwards disposable transducer cable output to Physio Control LifePak or Zoll Medical defibrillator input.

i cable IBP. Output of the Edwards TruWave disposable transducer cable to the LifePak LP12, LP15 or Zoll X, M  Series defibrillator, MS 6 pin IBP input.

Part #: ME590142R

Connects Respironics V60, V200, V1000, or Esprit series alarm output to the nurse call headwall jack.

i cable Nurse Call. 1/4″ phone plug three circuit alarm output of a Respironics V-60, V-200, V-1000 or Esprit series ventilator to the central station alarm monitoring system input, 1/4″ two circuit phone plug. An integrated switch allows a selection between ‘normally open or ‘ normally closed‘ system protocols. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590238E

Connects Puritan-Bennett ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. 4 pin Hirose normally open alarm output of  the Puritan Bennett 700, 740, 760, 840 or 980 series ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590143NO

Expands the number of inputs at the headwall for connection to the nurse call system.

i cable Nurse Call Multiplier. Normally open alarm input at headwall jack (1/4″ phone plug ) expanded to be three parallel 1/4″ phone jacks.  Use to increase the number of connected devices at the headwall, turning the average room into a more intensive care unit! This product is compatible with normally open device alarm cables.

Part #: ME590338J

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG or IBP. 1/4″ phone plug output of the Philips monitor or balloon pump to Philips/Siemens ultrasound or Edwards LifeSciences Vigilance II , HemoSphere monitor, 1/4″ AUX ECG input.  Also connects the 1/4″ IBP output jack of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the balloon pump, continuous cardiac output monitor or ultrasound, AUX ECG input. Maguire 257 and 414 Series Interconnect systems are designed to deliver synchronized waveforms and simultaneous audio signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590138-1

Connects Maquet ventilator alarm output to the nurse call headwall jack. (Copy)

i cable Nurse Call.  616 jack normally open alarm output of Maquet Servo-i, Servo-n, Servo-s and Servo-U ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590138

Connects Maquet ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call.  616 jack normally open alarm output of Maquet Servo-i, Servo-n, Servo-s and Servo-U ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590120

Connects Viasys, Pulmonetis, Carefusion ventilators alarm outputs to the nurse call headwall jack.

i cable Nurse Call. RJ11 normally open alarm output of Viasys/Pulmonetics LTV Series and Carefusion Enve ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590131

Connects Hamilton G5 ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of Hamilton G5 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590147

Connects GE Healthcare Engstrom Carestation, Carescape R860 ventilators alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of GE Healthcare Engstrom, Carestation and Carescape R860 ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590180

Connects Maquet-Datascope balloon pump output (specific models) to Philips Healthcare monitor input.

i cable IBP. 9 pin Hypertronics Low-Level BP output of the Getinge Datascope CS300, Maquet CardioSave balloon pump to the Philips monitor, 12 pin input. Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.

Part #: ME590220

Connects Hamilton ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of Hamilton Galileo, Raphael and G5 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590142H

Connects Respironics Trilogy EVO, 100, BiPAP V30 ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ9 normally closed alarm output of Respironics Trilogy EVO, 100, EV300 or BiPAP V30 ventilator to 1/4″ 2 circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME119K

Safeguard Medical Cables
with a Cable Leash Kit

Never lose or misplace vital cables again. Protect your assets by securing the interconnect cable to its related equipment. Having medical cables and equipment tethered ensures your readiness to connect every time! This 16-piece kit allows you to safe guard FOUR essential cables and includes cable leashes with adhesive tab ends, set screws, hex wrenches and alcohol swabs. *Interconnect adapters shown in image sold separately.

Part #: ME590257N

Adapts MINDRAY N1 monitors single output to be multiple phone jack outputs.

i cable ECG & IBP Multiplier. Mindray N1 Monitors output adapted to be  1/4″ two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP analog audio signal to desirable peripheral monitors. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590257P

Adapts GE Healthcare monitor single output to be multiple phone jack outputs.

i cable ECG & IBP Multiplier. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module adapted to be  1/4″ two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP signal to desirable peripheral monitors. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590185M

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG. 9 pin ‘Defib/Sync’ output of the GE Carescape One monitor or PDM module to balloon pump, Vigilance II,  Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.

Part #: ME590221

Adapts Philips Healthcare monitor or Maquet-Datascope balloon pump single output to be three outputs..

i cable ECG or IBP Multiplier. 1/4″ three circuit ECG output of the Philips monitor, Maquet-Datacope balloon pump or other 1/4″ output to be three parallel phone jacks. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. This multiplier not only expands the device’s single analog output, it can also expand the output of a MAGUIRE 257 Series multiplier or 414 Series Boom Cabling System. Use this product in combination with MAGUIRE multiplier cables to deliver ECG or IBP signal to desirable peripheral monitors. (excluding the bifurcated dual signal cable).  Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590248G

Adapts Draeger Medical monitor single output to be three outputs.

i cable ECG & IBP Multiplier. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series, Axiom Sensis, and M540 monitors adapted to be three parallel ECG and IBP outputs.  Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitors via 14 pin MDR interconnect cables.

Part #: ME590132

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump to GE Healthcare monitor or ultrasound input (specific models).

i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to specific GE device inputs, all monitors and ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin ECG input. Refer to part# ME590184F for connection to other GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590336

Connects Nihon Kohden output to Maquet-Datascope balloon pump input.

i cable ECG. 5 pin output from the Nihon Kohden monitor to the Maquet-Datascope balloon pump, 1/4 AUX ECG input.

Part #: ME590009XRN

Connects Zoll R Series defibrillator output to Philips Healthcare monitor, ultrasound input.

i cable ECG.  7 pin ‘Sync In/Marker Out’ of Zoll R Series Defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) to the  Philips monitor or ultrasound, 12 pin ECG input.

Part #: ME550ZRN

Adapts Zoll R Series defibrillator output to Cardiac Rhythm Management Pacer Programmer cables.

i cable ECG Adapter. 7 pin ‘Sync In/Marker Out‘ of Zoll R Series defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) adapted to mate with CRM pacemaker programmer cables via the 1/4″ two circuit phone jack. See also our multi-defibrillator adapter, part# ME550DFB3.

Part #: ME590185P

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable  ECG & IBP. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5  IVUS Imaging System, 1/4″ 2 circuit phone plug AUX ECG & IBP inputs.

Part #: ME550DFB3
Part #: ME590265P

Connects Maguire multiplier/adapters or Boom Cabling system outputs to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multipliers or MAGUIRE 414 Series Boom Cabling System to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.  Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590264

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG.  7 pin mini DIN “Defib Sync” output of GE monitor to balloon pump, Vigilance II,  Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.

Part #: ME590145F

Connects Viasys, Respironics, Cardinal Health, Carefusion VELA or AVEA ventilators alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ12 normally open alarm output of Viasys, Cardinal Health, Carefusion Vela or Avea Series ventilators to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.