Part #: ME590142R

Connects Respironics V60, V200, V1000, or Esprit series alarm output to the nurse call headwall jack.

i cable Nurse Call. 1/4″ phone plug three circuit alarm output of a Respironics V-60, V-200, V-1000 or Esprit series ventilator to the central station alarm monitoring system input, 1/4″ two circuit phone plug. An integrated switch allows a selection between ‘normally open or ‘ normally closed‘ system protocols. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590142H

Connects Respironics Trilogy EVO, 100, BiPAP V30 ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ9 normally closed alarm output of Respironics Trilogy EVO, 100, EV300 or BiPAP V30 ventilator to 1/4″ 2 circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590142K

Connects Respironics Trilogy EVO, 100, BiPAP V30 ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ9 normally open alarm output of Respironics Trilogy EVO, 100, or BiPAP V30 ventilator output to 1/4″ 2 circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590258N

Connects Respironics BiPAP Vision ventilator alarm output to the nurse call headwall jack.

i cable Nurse Call. BNC alarm output of Philips Respironics BiPAP Vision (not ESPRIT) ventilator alarm output to a 1/4″ two circuit right angle phone plug. Device settings will determine open/closed status. Click to view related info regarding equipment normally open/closed protocol.

When used as normally open, this device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590135G

Connects Dixtal Novametrix pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. DB25 normally open alarm output of Dixtal Novametrix SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug.This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590200F

Connects Respironics Criterion Sleep System monitor alarm output to the nurse call headwall jack.

i cable Nurse Call. DB9 normally open alarm output of Respironics Criterion 40 airway pressure diagnostic sleep system monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.