Same Day Shipping
On many popular products
Showing all 7 results
i cable Nurse Call. 1/4″ two circuit phone plug alarm output of Hospira/Abbott Plum A infusion pump or Masimo ROOT monitor, Rad 8, Rad 87 and Rad 97 pulse oximeter to a 1/4″ two circuit right angle phone plug. Some device settings will determine open/closed status. When used with a normally open system protocol this device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call normally open output of Philips Intellivue MX750 and MX 800 monitor RJ12 to 1/4″ 2 ckt right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow up to three device connections.
i cable Nurse Call. 1/8″ three circuit normally open alarm output of Covidien Oridion Capnostream 20 CO2 monitor, Philips SureSigns VSi, VS2, VS3, VS4 ,Welch Allyn VSM 6000, Vapotherm Precision Flow Ventilator and Invent HT150 monitors to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. 14 pin MDR normally open alarm output of Spacelabs 91369, 91370, 90387, Qube and Xpreazzon monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. RJ12 normally open alarm output of Spacelabs 90385 monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. DB9 normally open alarm output of Respironics Criterion 40 airway pressure diagnostic sleep system monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. 1/4″ two circuit right angle normally open alarm output of Masimo ROOT patient monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.