Part #: ME590142E

Connects Hospira/Abbott infusion pump or Masimo monitor, pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call.  1/4″ two circuit phone plug alarm output of Hospira/Abbott Plum A infusion pump or Masimo ROOT monitor, Rad 8, Rad 87 and Rad 97 pulse oximeter to a 1/4″ two circuit right angle phone plug. Some device settings will determine open/closed status. When used with a normally open system protocol this device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590148

Connects Masimo Radical 7 pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15HD normally open alarm output of Masimo Radical 7 SpO2 Pulse Oximeter to 1/4″ 2 ckt right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590135

Connects Covidien Nellcor pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. DB15 normally open alarm output of Covidien Nellcor N-395, N-560, N-595, N-600 and PM1000N pulse oximeter to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590145J

Connects Nellcor Covidien pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ12 normally open alarm output of Nellcor PM100N SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590145G

Connects Philips Healthcare Intellivue MX750 and MX800 monitor output to the nurse call headwall jack.

i cable Nurse Call normally open output of Philips Intellivue MX750 and MX 800 monitor RJ12 to 1/4″ 2 ckt right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow up to three device connections.

Part #: ME590135G

Connects Dixtal Novametrix pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. DB25 normally open alarm output of Dixtal Novametrix SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug.This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.

Part #: ME590145K

Connects Covidien Nellcor pulse oximeter alarm output to the nurse call headwall jack.

i cable Nurse Call. RJ12 normally closed output of Covidien Nellcor PM100N SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug.