Showing all 7 results

Show sidebar
Part #: ME590132

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump to GE Healthcare monitor or ultrasound input (specific models).

i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to specific GE device inputs, all monitors and ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin ECG input. Refer to part# ME590184F for connection to other GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590185Q

Connects GE Healthcare monitor output to GE Healthcare monitor or ultrasound input (specific models).

i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to all GE monitors and specific ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin patient ECG input.

Part #: ME590015P

Connects Draeger Medical monitor output to GE Healthcare monitor or ultrasound input (specific models).

i cable ECG. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta and M540 monitor (not including Axiom Sensis ) to all GE monitors and select ultrasound models: Vivid 5, 7, E9, E95, 11 pin patient ECG input. NOTE: connection from M540 monitor requires adapter #MS20662 available from Draeger.

Part #: ME579G

Extends the GE Healthcare 3, 5, or 10 wire patient cable.

i cable ECG Extension. 11 pin GE patient cable extended for 3 wire, 5 wire or 10 wire ECG cables. 6 foot length.

Part #: ME590185F

Connects GE Healthcare monitor output to GE ultrasound input (specific models)

i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to Vivid i or Vivid Q ultrasound, 7 pin Redel AUX ECG input.

Part #: ME590184F

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to GE Healthcare ultrasound input (select models).

i cable ECG. 1/4″ phone plug output of the Philips monitor or  balloon pump to GE ultrasound S5, S6, S60 and S70,  11 pin ECG input. Refer to part# ME590132 for connection to other  GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590269

Connects GE Healthcare monitor output to GE Healthcare monitor and ultrasound input (select models).

i cable ECG. 7 pin mini DIN ‘Defib Sync’ output  of GE monitor to all GE monitors and select ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin ECG patient input.