ECG & IBP Dual Cables transfer both physiologic signals and waveforms from one physiologic monitor to another monitor or system. Dual signal cables are invaluable when interconnecting balloon pumps and continuous cardiac output monitors.

Showing all 9 results

Show sidebar
Part #: ME590185P

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable  ECG & IBP. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5  IVUS Imaging System, 1/4″ 2 circuit phone plug AUX ECG & IBP inputs.

Part #: ME590265P

Connects Maguire multiplier/adapters or Boom Cabling system outputs to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multipliers or MAGUIRE 414 Series Boom Cabling System to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.  Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590265E

Connects Philips Healthcare monitor and blood pressure module output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable ECG & IBP. 1/4″ (6.35mm) phone plug (green) and 1/8″ (3.5mm) phone plug (red) output of the Philips monitor with blood pressure module to the CardioSave, CS100, CS300, or Arrow balloon pump or to the Volcano S5 IVUS Imaging System, 1/4″ (6.35mm) phone plug AUX ECG & IBP inputs.

Part #: ME590185H

Connects GE Healthcare monitor output to Edwards LifeSciences CCO monitor input.

i cable ECG and IBP. 9 pin ‘Defib/Sync’ output  of the GE Healthcare Monitor Carescape One and PDM module to Edwards Hemosphere or Vigilance II monitor as a 1/4″ (6.35mm) green phone plug AUX ECG and 1/8″ (3.5mm) red phone plug IBP inputs.

Part #: ME590265

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable ECG & IBP. 7 pin mini DIN “Defib Sync” output of the GE monitor to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ phone plug AUX ECG & IBP inputs.

Part #: ME590265H

Connects Maguire multiplier or Boom Cabling system outputs to Edwards LifeSciences monitor inputs.

i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the Edwards Vigilance II or Hemosphere, 1/4″ two circuit red phone plug AUX ECG input and 1/8″ (3.5mm) green two circuit phone plug IBP input.  Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590032P

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable GE Healthcare monitors 6 pin LEMO ECG output to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.

Part #: ME590092

Connects Draeger Siemens monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series Monitors (not including Axiom Sensis) 14 pin MDR output to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.  NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger.

Part #: YJ-920P

Adapts Nihon Kohden monitor analog output.

i cable ECG & IBP Adapter. This Nihon Kohden adapter is used to adapt the NK monitor to provide one ECG and one IBP signal via 1/4″ phone jacks. Use the adapter in tandem with the MAGUIRE 257 Series Output Multiplier System which allows simultaneous signal transfer to multiple devices via MAGUIRE multiplier interconnect cables.