i cable Nurse Call. DB15HD normally open alarm output of Masimo Radical 7 SpO2 Pulse Oximeter to 1/4″ 2 ckt right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. DB15 normally open alarm output of Covidien Nellcor N-395, N-560, N-595, N-600 and PM1000N pulse oximeter to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. Normally closed alarm output of ResMed Astral 150 ventilator. Includes 2 pieces uniquely engineered to improve the ruggedness of the vent alarm output. 1) Adapter ME550ASTRALC: 5 pin to 1/8″ phone jack and 2) Alarm cable ME590333N: 1/8″ two circuit phone plug to 1/4″ two circuit right angle phone plug.
i cable Nurse Call. RJ9 4P4C normally open alarm output of Ventec Life Systems VOCSN ventilator to the central station monitoring system, 1/4″ two circuit right angle phone plug input. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. 6 pin DIN normally open alarm output of Draeger Evita 2, 4, & XL or Savina ventilator to a 1/4″ two circuit right angle phone plug. Not for use with Infinity Series. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. Normally open alarm output of GE Healthcare Carestation or Carescape R860 ventilator to the input at the headwall jack which transmits device alarms to the central nurses station. Set includes 2 pieces: 1) DB15 to 1/4″ 2 circuit right angle phone plug. 10 ft length. 2) Required GE isolation cable #2070436-001. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. RJ12 normally open alarm output of Nellcor PM100N SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call normally open output of Philips Intellivue MX750 and MX 800 monitor RJ12 to 1/4″ 2 ckt right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow up to three device connections.
i cable Nurse Call – Data. GE Healthcare R860 Ventilator DB15 to Nurse Call and EMR system inputs.
i cable Nurse Call. 8 pin Hirose normally open alarm output of Puritan Bennett Covidien 540 ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. 6 pin mini DIN normally open alarm output of Datex-Ohmeda TruSat ventilator to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. DB25 normally open alarm output of Dixtal Novametrix SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug.This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. RJ12 normally closed output of Covidien Nellcor PM100N SpO2 pulse oximeter to a 1/4″ two circuit right angle phone plug.
i cable Nurse Call. 1/8″ three circuit normally open alarm output of Covidien Oridion Capnostream 20 CO2 monitor, Philips SureSigns VSi, VS2, VS3, VS4 ,Welch Allyn VSM 6000, Vapotherm Precision Flow Ventilator and Invent HT150 monitors to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. RJ12 normally open alarm output of ICU Medical Plum 360 infusion pump to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. 14 pin MDR normally open alarm output of Spacelabs 91369, 91370, 90387, Qube and Xpreazzon monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable ECG. DB15HD output of Physio-Control Lifepak LP20 defibrillator to Biotronik Renamic and ICS 3000 Pacer Programmer ECG input.
i cable Nurse Call. 4 pin AMP normally open alarm output of Prismaflex System to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. RJ12 normally open alarm output of Spacelabs 90385 monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series Monitors (not including Axiom Sensis) 14 pin MDR output to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger.
i cable ECG. 1/8″ (3.5mm) two circuit phone plug output of Zoll Medical PD and M Series, CCT and Welch Allyn defibrillators to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor or Philips-Siemens ultrasound, 1/4″ (6.35mm) two circuit phone plug AUX ECG input.
i cable ECG. 9 pin Hypertronics output of Physio-Control LifePak LP12 and LP15 to the Boston Scientific ZOOM Pacer Programmer input, AAMI 6 pin ECG input.
i cable ECG Adapter. 14 pin MDR output of Draeger Delta or Delta XL monitor (not including the AXIOM SENSIS) adapted to mate with CRM pacemaker programmer cable via the 1/4″ two circuit phone jack. Use in tandem with 1/4″ phone plug pacer programmer cables. This adapter also enables connection to other physiologic monitors via 1/4″ phone plug accessory cables.
i cable ECG Adapter. TT253 ‘HLo’ output of the Spacelabs module adapted to mate with CRM pacemaker programmer cable via the 1/4″ two circuit phone jack. Use in tandem with 1/4″ phone plug pacer programmer cables. This adapter also enables connection to other physiologic monitors via 1/4″ phone plug accessory cables.
i cable ECG Adapter. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module adapted to mate with CRM pacemaker programmer cable via the 1/4″ two circuit phone jack. Use in tandem with 1/4″ phone plug pacer programmer cables. This adapter also enables connection to other physiologic monitors via 1/4″ phone plug accessory cables.
i cable ECG Adapter. 7 pin mini DIN output of GE monitor adapted to mate with CRM pacemaker programmer cable via the 1/4″ two circuit phone jack. Use in tandem with 1/4″ phone plug pacer programmer cables. This adapter also enables connection to other physiologic monitors via 1/4″ phone plug accessory cables.
i cable ECG. 7 pin ‘Sync In/Marker Out’ of Zoll R Series Defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) to Biotronik Renamic and ICS 3000 Pacer Programmer ECG input.
i cable ECG & IBP Multiplier. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series and M540 Monitors (not including Axiom Sensis) adapted to be 1/4″ two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP signal to desirable peripheral monitors. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG & IBP Multiplier. HLO (J10) DB15HD output of the Spacelabs monitor adapted to be 1/4″ two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, continuous cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP signal to desirable peripheral monitors. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG & IBP Multiplier. 7 pin mini DIN output of GE Healthcare monitor or Tram Module to be three parallel 7 pin mini DIN ECG & IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitors via 7 pin mini DIN interconnect cables.