Additional information
Signal Type | |
---|---|
Connects from (signal source - HOST output) | |
Connects to (signal destination - input) | |
Compatible with (OEM) |
On many popular products
Speak to our experts
Safe & Secure checkout
We accept Purchase Orders
$284
i cable IBP. Output of Abbott / Hospira, Medex, ICU Medical Transpac 4 transducer cable to Draeger Infinity Series monitor, IBP input. Requires the use of Draeger #5731281E530U IBP Y cable.
Signal Type | |
---|---|
Connects from (signal source - HOST output) | |
Connects to (signal destination - input) | |
Compatible with (OEM) |
Adapter -Input- Philips Healthcare 12 pin IBP input to Physio-Control LifePak LP12, LP15; Zoll M, X and CCT Series Defibrillators MS 6 pin IBP input. 6 inch length.
i cable IBP. 9 pin Hypertronics low level blood pressure output of Datascope CS300 or Maquet Cardiosave balloon pump to the Draeger Infinity Series monitor input (requires Draeger 5731281E530U IBP Y cable). Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.
i cable ECG & IBP Multiplier. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series and M540 Monitors (not including Axiom Sensis) adapted to be 1/4″ two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP signal to desirable peripheral monitors. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable IBP. Output of the Edwards TruWave disposable transducer cable to the LifePak LP12, LP15 or Zoll X, M Series defibrillator, MS 6 pin IBP input.
i cable ECG. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series Monitors (not including Axiom Sensis) to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger.
i cable ECG Adapter. 14 pin MDR output of Draeger Delta or Delta XL monitor (not including the AXIOM SENSIS) adapted to mate with CRM pacemaker programmer cable via the 1/4″ two circuit phone jack. Use in tandem with 1/4″ phone plug pacer programmer cables. This adapter also enables connection to other physiologic monitors via 1/4″ phone plug accessory cables.
i cable Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series Monitors (not including Axiom Sensis) 14 pin MDR output to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger.