Showing 1–12 of 16 results

Show sidebar
Part #: ME550DFB3

Output Adapter for use with Zoll Medical R Series and Physio-Control LifePak defibrillators.

Connects the Physio-Control and Zoll Medical defibrillator outputs to CRM Pacer Programmer cables.

Part #: ME590335

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to Zoll Medical defibrillator input or ultrasound input.

i cable ECG. 1/4″ phone plug output from the Philips monitor or Maquet-Datascope balloon pump to the Zoll R, X and M series defibrillator ECG input. Also from the Philips monitor to the balloon pump input or ultrasound, AAMI 6 pin ECG input. Compatible with MAGUIRE 257 Series Multipliers or MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590030

Adapts the Zoll Medical defibrillator patient ECG input to accept a Philips Healthcare patient cable.

i cable ECG Adapter. 12 pin Philips ECG patient cable adapted to mate with ZOLL X, R, M series defibrillator, AAMI 6 pin ECG input. When tethered to the defibrillator or defibrillator crash cart, it enables a compatible connection for speedy diagnosis and delivery of care.

Part #: ME550ZRN

Adapts Zoll R Series defibrillator output to Cardiac Rhythm Management Pacer Programmer cables.

i cable ECG Adapter. 7 pin ‘Sync In/Marker Out‘ of Zoll R Series defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) adapted to mate with CRM pacemaker programmer cables via the 1/4″ two circuit phone jack. See also our multi-defibrillator adapter, part# ME550DFB3.

Part #: ME584F

Connects Edwards disposable transducer cable output to Physio Control LifePak or Zoll Medical defibrillator input.

i cable IBP. Output of the Edwards TruWave disposable transducer cable to the LifePak LP12, LP15 or Zoll X, M  Series defibrillator, MS 6 pin IBP input.

Part #: ME590185

Connects GE Healthcare monitor output to Zoll Medical defibrillator input.

i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to Zoll X, R or M Series, AAMI 6 pin patient ECG input.

Part #: ME581

Adapts the Physio Control LifePak defibrillator invasive pressure input to accept a GE Healthcare pressure cable.

i cable IBP Adapter. 11 pin GE invasive blood pressure cable adapted to mate with LifePak LP12, LP15 or Zoll X, M Series defibrillator, MS 6 pin IBP input. When tethered to the defibrillator or defibrillator crash cart, it enables a compatible connection for speedy diagnosis and delivery of care.

Part #: ME583R

Adapts the Zoll Medical defibrillator input to accept a Philips Healthcare pressure cable.

i cable IBP Adapter.  Philips Healthcare 12 pin invasive blood pressure cable adapted to mate with the Zoll X and M Series defibrillator, MS 6 pin IBP input. When tethered to the defibrillator or defibrillator crash cart, it enables a compatible connection for speedy diagnosis and delivery of care.

Part #: ME590359

Connects Spacelabs Healthcare monitor output to the Zoll defibrillator input or balloon pump input.

i cable ECG. TT253 ‘HLo’ output of Spacelabs Healthcare monitor to Zoll Medical defibrillator or Maquet-Datascope balloon pump, 6 pin AAMI patient ECG input.

Part #: ME579

Extends the 6 pin AAMI patient cable.

i cable ECG Extension. 6 pin AAMI patient cable extended for ECG patient cables. 6 foot length.

Part #: ME590301RN

Connects Zoll Medical R series defibrillator output to Maquet-Datascope balloon pump or ultrasound input.

i cable ECG.  7 pin ‘Sync In/Marker Out’ of Zoll R Series Defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) to balloon pump or ultrasound, AAMI 6 pin ECG input.

Part #: ME590180M

Connects Maquet-Datascope balloon pump (specific models) to Physio Control LifePak and Zoll Medical defibrillator input.

i cable IBP. 9 pin Hypertronics low level blood pressure output of Datascope CS300 or Maquet Cardiosave balloon pump to the LifePak defibrillator LP12, LP15, LP20, LP20e with Code Management Module,  or Zoll X, M Series defibrillators, MS 6 pin IBP input. Uses the BP transducer of the balloon pump to provide pressure information to the defibrillator.