i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to the LifePak defibrillator LP12, LP15, LP20, LP20e with code management module, 12 pin ECG input. This cable is also compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 1/4″ phone plug output from the Philips monitor or Maquet-Datascope balloon pump to the Zoll R, X and M series defibrillator ECG input. Also from the Philips monitor to the balloon pump input or ultrasound, AAMI 6 pin ECG input. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized analog audio waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG or IBP. 1/4″ phone plug output of the Philips monitor or balloon pump to Philips/Siemens ultrasound or Edwards LifeSciences Vigilance II , HemoSphere monitor, 1/4″ AUX ECG input. Also connects the 1/4″ IBP output jack of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the balloon pump, continuous cardiac output monitor or ultrasound, AUX ECG input. Maguire 257 and 414 Series Interconnect systems are designed to deliver synchronized waveforms and simultaneous audio signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable IBP. 9 pin Hypertronics Low-Level BP output of the Getinge Datascope CS300, Maquet CardioSave balloon pump to the Philips monitor, 12 pin input. Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.
i cable ECG or IBP Multiplier. 1/4″ three circuit ECG output of the Philips monitor, Maquet-Datacope balloon pump or other 1/4″ output to be three parallel phone jacks. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. This multiplier not only expands the device’s single analog output, it can also expand the output of a MAGUIRE 257 Series multiplier or 414 Series Boom Cabling System. Use this product in combination with MAGUIRE multiplier cables to deliver ECG or IBP signal to desirable peripheral monitors. (excluding the bifurcated dual signal cable). Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 5 pin output from the Nihon Kohden monitor to the Maquet-Datascope balloon pump, 1/4 AUX ECG input.
i cable ECG & IBP. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ 2 circuit phone plug AUX ECG & IBP inputs.
i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multipliers or MAGUIRE 414 Series Boom Cabling System to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs. Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 7 pin mini DIN “Defib Sync” output of GE monitor to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.
i cable ECG or IBP. TT253 ‘HLo’ output of the Spacelabs monitor module to balloon pump, AUX ECG or IBP. Also connects to Vigilance II, Hemosphere continuous cardiac output monitor or Philips Healthcare, Siemens ultrasound AUX ECG input, 1/4″ two circuit phone plug input.
i cable ECG & IBP. 1/4″ (6.35mm) phone plug (green) and 1/8″ (3.5mm) phone plug (red) output of the Philips monitor with blood pressure module to the CardioSave, CS100, CS300, or Arrow balloon pump or to the Volcano S5 IVUS Imaging System, 1/4″ (6.35mm) phone plug AUX ECG & IBP inputs.
i cable IBP. 9 pin Hypertronics low level blood pressure output of Datascope CS300 or Maquet Cardiosave balloon pump to the GE Healthcare monitor input. Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.
i cable ECG & IBP. 7 pin mini DIN “Defib Sync” output of the GE monitor to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ phone plug AUX ECG & IBP inputs.
i cable Extension. 1/4″ two circuit phone plug adapted to 1/4″ two circuit phone jack. For use with AUX ECG or IBP inputs. 6 foot length.
i cable ECG. TT253 ‘HLo’ output of Spacelabs Healthcare monitor to Zoll Medical defibrillator or Maquet-Datascope balloon pump, 6 pin AAMI patient ECG input.
i cable ECG Extension. 6 pin AAMI patient cable extended for ECG patient cables. 6 foot length.
i cable ECG. 1/8″ two circuit phone plug output of the Zoll Medical PD and M Series, CCT or Welch Allyn defibrillators to the Getinge-Maquet-Datascope balloon pump or ultrasound, AAMI 6 pin ECG input.
i cable IBP. 9 pin Hypertronics low level blood pressure output of Datascope CS300 or Maquet Cardiosave balloon pump to the Draeger Infinity Series monitor input (requires Draeger 5731281E530U IBP Y cable). Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.
i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to GE ultrasound S5, S6, S60 and S70, 11 pin ECG input. Refer to part# ME590132 for connection to other GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG & IBP. TT253 ‘HLo’ output of the Spacelabs module to balloon pump, 1/4″ AUX ECG & IBP inputs. Also connects to the Volcano S5 IVUS Imaging System, AUX ECG & IBP inputs.
i cable ECG. 6 pin LEMO output of GE monitor to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.
i cable IBP. 1/8″ (3.5mm) three circuit phone plug output of the Philips blood pressure module to the Maquet-Datascope balloon pump, 1/4″ (6.35mm) three circuit phone plug AUX IBP input.
i cable GE Healthcare monitors 6 pin LEMO ECG output to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.
i cable ECG. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series Monitors (not including Axiom Sensis) to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger.
i cable ECG. 1/8″ (3.5mm) two circuit phone plug output of Zoll Medical PD and M Series, CCT and Welch Allyn defibrillators to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor or Philips-Siemens ultrasound, 1/4″ (6.35mm) two circuit phone plug AUX ECG input.