Showing all 25 results

Show sidebar
Part #: ME590006K

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump to Physio Control LifePak defibrillator input.

i cable ECG. 1/4″ phone plug output of the Philips monitor or  balloon pump to the LifePak defibrillator LP12, LP15, LP20, LP20e with code management module, 12 pin ECG input. This cable is also compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590335

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to Zoll Medical defibrillator input or ultrasound input.

i cable ECG. 1/4″ phone plug output from the Philips monitor or Maquet-Datascope balloon pump to the Zoll R, X and M series defibrillator ECG input. Also from the Philips monitor to the balloon pump input or ultrasound, AAMI 6 pin ECG input. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized analog audio waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590338J

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG or IBP. 1/4″ phone plug output of the Philips monitor or balloon pump to Philips/Siemens ultrasound or Edwards LifeSciences Vigilance II , HemoSphere monitor, 1/4″ AUX ECG input.  Also connects the 1/4″ IBP output jack of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the balloon pump, continuous cardiac output monitor or ultrasound, AUX ECG input. Maguire 257 and 414 Series Interconnect systems are designed to deliver synchronized waveforms and simultaneous audio signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590180

Connects Maquet-Datascope balloon pump output (specific models) to Philips Healthcare monitor input.

i cable IBP. 9 pin Hypertronics Low-Level BP output of the Getinge Datascope CS300, Maquet CardioSave balloon pump to the Philips monitor, 12 pin input. Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.

Part #: ME590221

Adapts Philips Healthcare monitor or Maquet-Datascope balloon pump single output to be three outputs..

i cable ECG or IBP Multiplier. 1/4″ three circuit ECG output of the Philips monitor, Maquet-Datacope balloon pump or other 1/4″ output to be three parallel phone jacks. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. This multiplier not only expands the device’s single analog output, it can also expand the output of a MAGUIRE 257 Series multiplier or 414 Series Boom Cabling System. Use this product in combination with MAGUIRE multiplier cables to deliver ECG or IBP signal to desirable peripheral monitors. (excluding the bifurcated dual signal cable).  Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590336

Connects Nihon Kohden output to Maquet-Datascope balloon pump input.

i cable ECG. 5 pin output from the Nihon Kohden monitor to the Maquet-Datascope balloon pump, 1/4 AUX ECG input.

Part #: ME590185P

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable  ECG & IBP. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5  IVUS Imaging System, 1/4″ 2 circuit phone plug AUX ECG & IBP inputs.

Part #: ME590265P

Connects Maguire multiplier/adapters or Boom Cabling system outputs to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multipliers or MAGUIRE 414 Series Boom Cabling System to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.  Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590264

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG.  7 pin mini DIN “Defib Sync” output of GE monitor to balloon pump, Vigilance II,  Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.

Part #: ME590027

Connects Spacelabs monitor output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG or IBP. TT253 ‘HLo’ output of the Spacelabs monitor module to balloon pump, AUX ECG or IBP. Also connects to Vigilance II, Hemosphere continuous cardiac output monitor or Philips Healthcare, Siemens ultrasound AUX ECG input,  1/4″ two circuit phone plug input.

Part #: ME590265E

Connects Philips Healthcare monitor and blood pressure module output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable ECG & IBP. 1/4″ (6.35mm) phone plug (green) and 1/8″ (3.5mm) phone plug (red) output of the Philips monitor with blood pressure module to the CardioSave, CS100, CS300, or Arrow balloon pump or to the Volcano S5 IVUS Imaging System, 1/4″ (6.35mm) phone plug AUX ECG & IBP inputs.

Part #: ME590180E

Connects Maquet-Datascope balloon pump output (specific models) to GE Healthcare monitor input.

i cable IBP. 9 pin Hypertronics low level blood pressure output of Datascope CS300 or Maquet Cardiosave balloon pump to the GE Healthcare monitor input. Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.

Part #: ME590265

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable ECG & IBP. 7 pin mini DIN “Defib Sync” output of the GE monitor to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ phone plug AUX ECG & IBP inputs.

Part #: ME590202F

Extends the 1/4″ phone plug cable connection.

i cable Extension. 1/4″ two circuit phone plug adapted to 1/4″ two circuit phone jack. For use with AUX ECG or IBP inputs. 6 foot length.

Part #: ME590359

Connects Spacelabs Healthcare monitor output to the Zoll defibrillator input or balloon pump input.

i cable ECG. TT253 ‘HLo’ output of Spacelabs Healthcare monitor to Zoll Medical defibrillator or Maquet-Datascope balloon pump, 6 pin AAMI patient ECG input.

Part #: ME579

Extends the 6 pin AAMI patient cable.

i cable ECG Extension. 6 pin AAMI patient cable extended for ECG patient cables. 6 foot length.

Part #: ME590301

Connects Zoll Medical M Series defibrillator output to Maquet-Datascope balloon pump input.

i cable ECG. 1/8″ two circuit phone plug output of the Zoll Medical PD and M Series, CCT or Welch Allyn defibrillators to the Getinge-Maquet-Datascope balloon pump or ultrasound, AAMI 6 pin ECG input.

Part #: ME590180H

Connects Maquet-Datascope balloon pump output (specific models) to Draeger monitor input.

i cable IBP. 9 pin Hypertronics low level blood pressure output of Datascope CS300 or Maquet Cardiosave balloon pump to the Draeger Infinity Series monitor input (requires Draeger 5731281E530U IBP Y cable). Uses the BP transducer of the balloon pump to provide pressure information to the primary monitor.

Part #: ME590184F

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to GE Healthcare ultrasound input (select models).

i cable ECG. 1/4″ phone plug output of the Philips monitor or  balloon pump to GE ultrasound S5, S6, S60 and S70,  11 pin ECG input. Refer to part# ME590132 for connection to other  GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590265S

Connects Spacelabs monitor output to Maquet-Datascope balloon pump of Philips Volcano Imaging System input.

i cable ECG & IBP.  TT253 ‘HLo’ output of the Spacelabs module to balloon pump, 1/4″ AUX ECG & IBP inputs. Also connects to the Volcano S5 IVUS Imaging System, AUX ECG & IBP inputs.

Part #: ME590027L

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable  ECG. 6 pin LEMO output of GE monitor to balloon pump, Vigilance II,  Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.

Part #: ME590333S

Connects Philips Healthcare blood pressure module to Maquet-Datascope balloon pump input.

i cable IBP. 1/8″ (3.5mm) three circuit phone plug output of the Philips blood pressure module to the Maquet-Datascope balloon pump, 1/4″ (6.35mm) three circuit phone plug AUX IBP input.

Part #: ME590032P

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable GE Healthcare monitors 6 pin LEMO ECG output to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.

Part #: ME590015L

Connects Draeger Siemens monitor to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor, or Philips-Siemens ultrasound input.

i cable ECG. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series Monitors (not including Axiom Sensis) to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger.

Part #: ME590333K

Connects Zoll Medical M Series defibrillator output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor Philips, Siemens ultrasound input.

i cable ECG.  1/8″ (3.5mm) two circuit phone plug output of Zoll Medical PD and M Series, CCT and Welch Allyn defibrillators to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor or Philips-Siemens ultrasound,  1/4″ (6.35mm) two circuit phone plug AUX ECG input.