i cable ECG & IBP Multiplier. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta Series and M540 Monitors (not including Axiom Sensis) adapted to be 1/4″ two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP signal to desirable peripheral monitors. NOTE: Connection from M540 monitor requires adapter #MS20662 available from Draeger. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG & IBP Multiplier. 7 pin mini DIN output of GE Healthcare monitor or Tram Module to be three parallel 7 pin mini DIN ECG & IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitors via 7 pin mini DIN interconnect cables.
i cable ECG & IBP Multiplier. 6 pin LEMO output of GE monitors or Tram module to be three parallel 6 pin LEMO ECG & IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor via ancillary interconnect cables.
i cable Nurse Call. DB9 normally open alarm output of Respironics Criterion 40 airway pressure diagnostic sleep system monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable Nurse Call. 1/4″ two circuit right angle normally open alarm output of Masimo ROOT patient monitor to a 1/4″ two circuit right angle phone plug. This device alarm cable is compatible with the Maguire Device Alarm Input Multiplier, which expands the headwall jack to allow simultaneous monitoring of up to three devices.
i cable ECG or IBP Multiplier. 1/8″ (3.5mm) three circuit phone plug IBP output of Philips blood pressure module or ECG output of the Zoll M Series defibrillator adapted to be three 1/4″ (6.35mm) phone jacks. Allows simultaneous connection to a defibrillator, balloon pump, ultrasound, pacer programmer or other physiologic monitor via MAGUIRE multiplier cables (excluding bifurcated dual signal cables). Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG & IBP Adapter. This Nihon Kohden adapter is used to adapt the NK monitor to provide one ECG and one IBP signal via 1/4″ phone jacks. Use the adapter in tandem with the MAGUIRE 257 Series Output Multiplier System which allows simultaneous signal transfer to multiple devices via MAGUIRE multiplier interconnect cables.