Part #: ME590221

Adapts Philips Healthcare monitor or Maquet-Datascope balloon pump single output to be three outputs..

i cable ECG or IBP Multiplier. 1/4″ three circuit ECG output of the Philips monitor, Maquet-Datacope balloon pump or other 1/4″ output to be three parallel phone jacks. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. This multiplier not only expands the device’s single analog output, it can also expand the output of a MAGUIRE 257 Series multiplier or 414 Series Boom Cabling System. Use this product in combination with MAGUIRE multiplier cables to deliver ECG or IBP signal to desirable peripheral monitors. (excluding the bifurcated dual signal cable).  Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590185P

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable  ECG & IBP. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5  IVUS Imaging System, 1/4″ 2 circuit phone plug AUX ECG & IBP inputs.

Part #: ME590265P

Connects Maguire multiplier/adapters or Boom Cabling system outputs to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multipliers or MAGUIRE 414 Series Boom Cabling System to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.  Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590265E

Connects Philips Healthcare monitor and blood pressure module output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable ECG & IBP. 1/4″ (6.35mm) phone plug (green) and 1/8″ (3.5mm) phone plug (red) output of the Philips monitor with blood pressure module to the CardioSave, CS100, CS300, or Arrow balloon pump or to the Volcano S5 IVUS Imaging System, 1/4″ (6.35mm) phone plug AUX ECG & IBP inputs.

Part #: ME590265

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable ECG & IBP. 7 pin mini DIN “Defib Sync” output of the GE monitor to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ phone plug AUX ECG & IBP inputs.

Part #: ME590265S

Connects Spacelabs monitor output to Maquet-Datascope balloon pump of Philips Volcano Imaging System input.

i cable ECG & IBP.  TT253 ‘HLo’ output of the Spacelabs module to balloon pump, 1/4″ AUX ECG & IBP inputs. Also connects to the Volcano S5 IVUS Imaging System, AUX ECG & IBP inputs.

Part #: ME590032P

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable GE Healthcare monitors 6 pin LEMO ECG output to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.