Showing all 6 results

Show sidebar
Part #: ME590221

Adapts Philips Healthcare monitor or Maquet-Datascope balloon pump single output to be three outputs..

i cable ECG or IBP Multiplier. 1/4″ three circuit ECG output of the Philips monitor, Maquet-Datacope balloon pump or other 1/4″ output to be three parallel phone jacks. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, cardiac output or other connected physiologic monitor. This multiplier not only expands the device’s single analog output, it can also expand the output of a MAGUIRE 257 Series multiplier or 414 Series Boom Cabling System. Use this product in combination with MAGUIRE multiplier cables to deliver ECG or IBP signal to desirable peripheral monitors. (excluding the bifurcated dual signal cable).  Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590185P

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System input.

i cable  ECG & IBP. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5  IVUS Imaging System, 1/4″ 2 circuit phone plug AUX ECG & IBP inputs.

Part #: ME590265E

Connects Philips Healthcare monitor and blood pressure module output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable ECG & IBP. 1/4″ (6.35mm) phone plug (green) and 1/8″ (3.5mm) phone plug (red) output of the Philips monitor with blood pressure module to the CardioSave, CS100, CS300, or Arrow balloon pump or to the Volcano S5 IVUS Imaging System, 1/4″ (6.35mm) phone plug AUX ECG & IBP inputs.

Part #: ME590265

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable ECG & IBP. 7 pin mini DIN “Defib Sync” output of the GE monitor to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ phone plug AUX ECG & IBP inputs.

Part #: ME590257S

Adapts Philips Healthcare monitor & BP module single output to be multiple phone jack outputs.

i cable ECG & IBP Multiplier. 1/4″ (6.35mm) ECG  and 1/8″ (3.5mm) IBP bifurcated cable output of Philips Healthcare monitor and module adapted to be  1/4″ (6.35mm) two circuit phone jacks, 4 ECG and 2 IBP outputs. Allows simultaneous connection to defibrillator, balloon pump, ultrasound, pacer programmer, continuous cardiac output or other connected physiologic monitor. Use this product in combination with MAGUIRE multiplier cables to deliver ECG and IBP signal to desirable peripheral monitors. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME590032P

Connects GE Healthcare monitor output to Maquet-Datascope balloon pump or Philips Volcano Imaging System inputs.

i cable GE Healthcare monitors 6 pin LEMO ECG output to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs.