i cable ECG or IBP. 1/4″ phone plug output of the Philips monitor or balloon pump to Philips/Siemens ultrasound or Edwards LifeSciences Vigilance II , HemoSphere monitor, 1/4″ AUX ECG input. Also connects the 1/4″ IBP output jack of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the balloon pump, continuous cardiac output monitor or ultrasound, AUX ECG input. Maguire 257 and 414 Series Interconnect systems are designed to deliver synchronized waveforms and simultaneous audio signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 9 pin ‘Defib/Sync’ output of the GE Carescape One monitor or PDM module to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.
i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to specific GE device inputs, all monitors and ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin ECG input. Refer to part# ME590184F for connection to other GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 7 pin ‘Sync In/Marker Out’ of Zoll R Series Defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) to the Philips monitor or ultrasound, 12 pin ECG input.
i cable ECG & IBP. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ 2 circuit phone plug AUX ECG & IBP inputs.
i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multipliers or MAGUIRE 414 Series Boom Cabling System to the CardioSave CS100, CS300, Arrow balloon pumps, or Volcano S5 IVUS Imaging System, 1/4″ phone plug ECG & IBP inputs. Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 7 pin mini DIN “Defib Sync” output of GE monitor to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor, or Philips Healthcare and Siemens ultrasound, 1/4″ two circuit phone plug AUX ECG input.
i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to all GE monitors and specific ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin patient ECG input.
i cable ECG or IBP. TT253 ‘HLo’ output of the Spacelabs monitor module to balloon pump, AUX ECG or IBP. Also connects to Vigilance II, Hemosphere continuous cardiac output monitor or Philips Healthcare, Siemens ultrasound AUX ECG input, 1/4″ two circuit phone plug input.
i cable ECG & IBP. 1/4″ (6.35mm) phone plug (green) and 1/8″ (3.5mm) phone plug (red) output of the Philips monitor with blood pressure module to the CardioSave, CS100, CS300, or Arrow balloon pump or to the Volcano S5 IVUS Imaging System, 1/4″ (6.35mm) phone plug AUX ECG & IBP inputs.
i cable ECG and IBP. 9 pin ‘Defib/Sync’ output of the GE Healthcare Monitor Carescape One and PDM module to Edwards Hemosphere or Vigilance II monitor as a 1/4″ (6.35mm) green phone plug AUX ECG and 1/8″ (3.5mm) red phone plug IBP inputs.
i cable ECG & IBP. 7 pin mini DIN “Defib Sync” output of the GE monitor to CardioSave, CS100, CS300, or Arrow balloon pump or to Volcano S5 IVUS Imaging System, 1/4″ phone plug AUX ECG & IBP inputs.
i cable Extension. 1/4″ two circuit phone plug adapted to 1/4″ two circuit phone jack. For use with AUX ECG or IBP inputs. 6 foot length.
i cable ECG & IBP. 1/4″ phone plug outputs of the MAGUIRE 257 Series Multiplier or MAGUIRE 414 Series Boom Cabling System to the Edwards Vigilance II or Hemosphere, 1/4″ two circuit red phone plug AUX ECG input and 1/8″ (3.5mm) green two circuit phone plug IBP input. Maguire Interconnect Systems are designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable Extension. 1/8″ (3.5mm) temperature probe adapted to 1/4″ (6.35mm) phone plug temperature input.
i cable ECG. 14 pin MDR output of Draeger Siemens SC7000, SC8000, SC9000, Infinity Delta and M540 monitor (not including Axiom Sensis ) to all GE monitors and select ultrasound models: Vivid 5, 7, E9, E95, 11 pin patient ECG input. NOTE: connection from M540 monitor requires adapter #MS20662 available from Draeger.
i cable ECG Extension. 11 pin GE patient cable extended for 3 wire, 5 wire or 10 wire ECG cables. 6 foot length.
i cable ECG Extension. 6 pin AAMI patient cable extended for ECG patient cables. 6 foot length.
i cable ECG. Witt Series IV monitors with digital front end, BNC output to Zoll M, R, or X Series defibrillator, AAMI 6 pin ECG input.
i cable ECG. 6 pin LEMO output of the GE monitor to Zoll X, R or M Series, AAMI 6 pin ECG input.
i cable ECG. 14 pin MDR output of the Draeger -Siemens SC7000, SC8000, SC9000, Infinity Delta Series and M540 monitors (not including Axiom Sensis ) to Zoll R, X or M Series defibrillator, AAMI 6 pin ECG input. NOTE: connection from M540 monitor requires adapter #MS20662 available from Draeger.
i cable ECG. 1/8″ two circuit phone plug output of the Zoll Medical PD and M Series, CCT or Welch Allyn defibrillators to the Getinge-Maquet-Datascope balloon pump or ultrasound, AAMI 6 pin ECG input.
i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to Vivid i or Vivid Q ultrasound, 7 pin Redel AUX ECG input.
i cable ECG. 1/8″ (3.5mm) two circuit output of the Zoll PD and M defibrillator to the Philips monitor or ultrasound, 12 pin ECG input.
i cable ECG. TT253 ‘HLo’ output of Spacelabs modules to all GE monitors and select ultrasound models Vivid 5, 7, E9, E95, 11 pin patient ECG input.
i cable ECG. DB9 output of GE Case 8000, T2100 or Max 1 Stress Tester treadmill to all GE monitors and select ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin patient ECG input.
i cable ECG. 1/4″ two circuit phone plug output of the Philips monitor to Boston Scientific Zoom Programmer, AAMI 6 pin ECG input. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system. Is also compatible with MAGUIRE Multi-Defib Output Adapter.
i cable ECG. 1/4″ two circuit phone plug output of the Philips monitor or other 1/4″ phono plug output to the Biotronik Renamic & ICS 3000 Pacer Programmer ECG input. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system. Is also compatible with MAGUIRE Multi-Defib Output Adapter.
i cable ECG. 1/4″ phone plug output of the Philips monitor or balloon pump to GE ultrasound S5, S6, S60 and S70, 11 pin ECG input. Refer to part# ME590132 for connection to other GE Healthcare models. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.
i cable ECG. 7 pin mini DIN ‘Defib Sync’ output of GE monitor to all GE monitors and select ultrasound models Vivid 5, 7, E9, E95 and Logiq Series, 11 pin ECG patient input.