Showing all 9 results

Show sidebar
Part #: ME590335

Connects Philips Healthcare monitor or Maquet-Datascope balloon pump output to Zoll Medical defibrillator input or ultrasound input.

i cable ECG. 1/4″ phone plug output from the Philips monitor or Maquet-Datascope balloon pump to the Zoll R, X and M series defibrillator ECG input. Also from the Philips monitor to the balloon pump input or ultrasound, AAMI 6 pin ECG input. This cable is compatible with MAGUIRE 257 Series Multipliers and MAGUIRE 414 Series Boom Cabling System, each designed to deliver synchronized analog audio waveforms and simultaneous signal transfer onto multiple peripheral device displays. Learn how these low cost products simplify patient setup, reduce cable clutter and enhance any physiologic monitoring system.

Part #: ME550ZRN

Adapts Zoll R Series defibrillator output to Cardiac Rhythm Management Pacer Programmer cables.

i cable ECG Adapter. 7 pin ‘Sync In/Marker Out‘ of Zoll R Series defibrillator (model #AF14B034866 and higher or older models which were retrofitted with the female ECG output connector) adapted to mate with CRM pacemaker programmer cables via the 1/4″ two circuit phone jack. See also our multi-defibrillator adapter, part# ME550DFB3.

Part #: ME550DFB3
Part #: ME590185

Connects GE Healthcare monitor output to Zoll Medical defibrillator input.

i cable ECG. 9 pin ‘Defib/Sync’ output of GE Carescape One monitor or PDM module to Zoll X, R or M Series, AAMI 6 pin patient ECG input.

Part #: ME590359

Connects Spacelabs Healthcare monitor output to the Zoll defibrillator input or balloon pump input.

i cable ECG. TT253 ‘HLo’ output of Spacelabs Healthcare monitor to Zoll Medical defibrillator or Maquet-Datascope balloon pump, 6 pin AAMI patient ECG input.

Part #: ME579

Extends the 6 pin AAMI patient cable.

i cable ECG Extension. 6 pin AAMI patient cable extended for ECG patient cables. 6 foot length.

Part #: ME590230G

Adapts the Zoll Medical defibrillator patient input to accept a GE Healthcare patient cable.

i cable ECG Adapter. Allows the use of a GE Healthcare 3 or 5 wire patient ECG cable with the Zoll M, R or X Series defibrillator. GE Healthcare 11 pin ECG adapted to be Zoll 6 pin AAMI.

Part #: ME590207

Adapts the GE Healthcare patient ECG input to accept a Zoll Medical patient cable.

i cable ECG Adapter. AAMI 6 pin Zoll ECG patient cable adapted to mate with GE Healthcare monitor, 11 pin ECG input (not including S5 and S6 monitors). When tethered to the monitor, it enables a compatible connection for continuous vital signs monitoring.

Part #: ME590333K

Connects Zoll Medical M Series defibrillator output to Maquet-Datascope balloon pump, Edwards LifeSciences CCO monitor Philips, Siemens ultrasound input.

i cable ECG.  1/8″ (3.5mm) two circuit phone plug output of Zoll Medical PD and M Series, CCT and Welch Allyn defibrillators to balloon pump, Vigilance II, Hemosphere continuous cardiac output monitor or Philips-Siemens ultrasound,  1/4″ (6.35mm) two circuit phone plug AUX ECG input.